Double Ended Shear Beam Load Cell TD157

Feature:

Capacity range:20k to 150klb & 10t to 70t

Nickel plated alloy steel

Moisture protected

Trade certified for OIML 3,000D

Integral conduit adaptor

Temperature compensation,both zero and span

Center-link loaded

Compatible with international standard fixings

 

 
 
Capacity A B C D E G H L R
20k,25k,40klb 8.25 1.94 1.63 2.00 1.94 0.50 2.44 7.25 0.50
50k,60k,65k,100k,125k,150klb 10.25 3.00 2.05 2.40 2.20 1.00 3.00 8.50 1.00
10,20t 209.6 49.3 41.4 50.8 49.3 12.7 62 184.2 12.7
25,30,50,70t 260.4 76.2 52.1 61.0 55.9 25.4 76.2 215.9 25.4
 

Specifications

Rated output.......................................3mV/V±0.25%

Non-linearity.............................................0.03%FSO

Hysteresis...............................................0.03%FSO

Non-repeatability......................................0.02%FSO

Creep in 20minutes...................................0.03%FSO

Temperature effect span..................0.015%FSO/10ºC

Temperature effect zero...................0.026%FSO/10ºC

Compensated temperature range..............-10ºC~40ºC

Operating temperature range ...................-40ºC~80ºC

Zero balance.....................................................±1%

Input resistance...................................800±30 Ohms

Output resistance..................................700±5 Ohms

Safe overload..................................................150%

Ultimate overload.............................................300%

Excitation voltage..........................................10VDC

Maximum excitation voltage ..........................15VDC

Insulation resistance......................>2000 Meg-Ohms

Environmental protection....................................IP67

Cable length......................................................30ft

 

Cable colour code:

Red............................+ Excitation

Black..........................- Excitation

Green..............................+ Signal

White...............................- Signal